0
Home > Products > BLE ModulesHelp?
  • Quick Purchase
  • Please enter the model No. from below Model Sheet.

      Model Sheet
  • Manufacturer
 
BLE Modules
  Model: BBT-LSP12
Price: US $0 /piece
Quantity: Pieces
Color:
Frequency:
Total Price
Add To Wish List Contact Now
 

Item specifics

Main parameter parameter Description
Note
Distance
60m

TClear and open, antenna height 2.5 m, airspeed 1 Mbps.

FIFO
60byte

Single transmission maximum length

Crystal oscillator
24MHz

-

Modulation
GFSK

GFSK Mode

Package
SMD

-

Connector
1.27mm

-

Interface
UART

4800~230400bps

Size
19*13mm

-

Antenna
PCB

50Ω Impedance


Main parameter Min Typ Max Unit Note
Voltage supply
1.9 3.3 3.6 V ≥3.3 V ensures output power
Communication level
- 3.3 - V For 5V TTL, it may be at risk of burning down
Operating temperature
-40
- 85

-
Frequency
2400
- 2483.5
MHz
ISM band

Transmitting current

- 21
- mA
Instantaneous power consumption at 10 dBm output

Receiving current

- 6.1
- mA
-
Turn-off current
- 13.32
- μA
-

maximum emitting power

- 10 - dBm
-
Receiving sensitivity
- -96
- dBm
Air data rate: 1Mbps
Air data rate(GFSK)
125k
1M
2M
bps
Default 1Mbps


Product Description


Pin Defination

No.
Pin item Pin direction Application
1 GND
-

Ground wire, connect to the power reference ground.

2 PWM1
PWM Output

Green light corresponding to SIGMESH HSL

3 PWM2
PWM Output

Red light corresponding to SIGMESH HSL

4 NC
-

-

5 NC
-

-

6 DIO1
Input

Switch input foot, PA0 foot for TLSR8253.

7 DIO2
Input

Switch input foot, PA1 foot for TLSR8253.

8 NC
-

-

9 NC
-

-

10 SWM
-

-

11 SWS
-

-

12 NC
-

-

13 LINK
Output

Network indicator. High level of pilot foot output after network formation.

14 NC
-

-

15 PWM3
PWM Output

Blue light corresponding to SIGMESH HSL model

16 NC
-

-

17 TXD
Output

UART launch boot. Receive user's string of users.

18 RXD Input

UART receive boot, send to user string

19 VCC -

Power supply, range 1.9~3.6V (Proposed to increase external ceramic

filter capacitance)

20 GND -

Ground wire, connect to the power reference ground.

21 NC
-

-

22 NC
-

-

23 NC
-

-

24 NC
-

-

25 RST
Input

The chip reset triggers the input foot. It's working at low levels.

26 GND
-

Ground wire, connect to the power reference ground.

Contact Us